Main Features

✔ Capacitive-based fuel level sensors, installed in stationary tanks, and Generators. The LLS is connected to the Corona unit and sends the reading data for further fuel processing

Technical Specifications
Supply Voltage 7-50V
Speed of data transmission 1200 – 115200 (adjustable)
Standard length of probe 700, 1000, 1500, 2000, 2500, 3000 mm
Discrimination (resolution) 1 – 4095 / 1-1023 (depends on operation mode)
Rated power Maximum 0.4W
Temperature Range (Operating) -40°C to +80°C
Data output interface RS232 and EIA (RS) 485 Insulate
Dust and water splashes protection IP57